dc.contributor.advisor | Šklubalová, Zdeňka | |
dc.creator | Marková, Jana | |
dc.date.accessioned | 2022-07-25T14:59:48Z | |
dc.date.available | 2022-07-25T14:59:48Z | |
dc.date.issued | 2022 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11956/173595 | |
dc.description.abstract | Charles University, Faculty of Pharmacy in Hradec Králové Department of: Pharmaceutical technology Consultant: doc. PharmDr. Zdeňka Šklubalová, Ph.D. Student: Jana Marková Title of Thesis: Dosing of veterinary eye drops 1. The main purpose of this thesis was to find out, whether and to what extent the rate of dispensing, the dispending angle (90ř, 65ř, 45ř) and the volume of preparation (30 ml, 15 ml, 5 ml) had effected the mass of commercial eye drops for poultry vaccination. Drops were produced manually by using conventional dispensing system (plastic 30 ml dropper bottle and dropper tip) and by using a new prototype of semi-automatic device. The drop mass increased with increasing the rate of drop formation in every examined combination of factors. With decreasing of the dispensing angle, the drop mass decreased only in a case of constant rate dropping. In all other cases, especially with volume reduction to 15 ml and 5 ml, the drop size often increased due to the wetting of hemispherical dropper tip. As a result, higher variability of drop masses had occurred. With using the semi-automated prototype, the preparation volume had no impact on the final drop mass. On the other hand, higher variability of doses was noted for studied suspension eye drops. | en_US |
dc.description.abstract | Univerzita Karlova, Farmaceutická fakulta v Hradci Králové Katedra: Farmaceutická techonologie Školitel: doc. PharmDr. Zdeňka Šklubalová, Ph.D. Posluchač: Jana Marková Název diplomové práce: Dávkování veterinárních očních kapek 1. Cílem této diplomové práce bylo hodnocení vlivu rychlosti kapání, úhlu kapání (90ř, 65ř, 45ř) a objemu náplně lahvičky (30 ml, 15 ml, 5 ml) na hmotnost komerčních očních kapek určených k vakcinaci drůbeže. Kapky byly dispensovány manuálně z konvenčního dávkovacího systému (plastová 30 ml lahvička a kapátko) nebo pomocí prototypu poloautomatického dávkovacího zařízení. S vyšší dispenzační rychlostí se hmotnost kapek zvyšovala ve všech experimentálních kombinacích sledovaných v práci. Pro konvenční systém se při snížení dispenzačního úhlu hmotnost kapky snižovala pouze při konstantní rychlosti kapání, v ostatních situacích zejména při redukci objemu náplně na 15 ml a 5 ml se zvyšovala díky smáčení zaobleného kapátka. V důsledku toho rostla i variabilita dávky. Vliv objemu na výslednou hmotnost kapky byl při použití prototypu podle doporučení výrobcem nevýznamný. U studovaných suspenzních kapek však byla zaznamenána zvýšená variabilita dávky. | cs_CZ |
dc.language | Čeština | cs_CZ |
dc.language.iso | cs_CZ | |
dc.publisher | Univerzita Karlova, Farmaceutická fakulta v Hradci Králové | cs_CZ |
dc.subject | vlastnosti kapek | cs_CZ |
dc.subject | dávkovací zařízení | cs_CZ |
dc.subject | hmotnost kapky | cs_CZ |
dc.subject | variabilita | cs_CZ |
dc.subject | properties of drops | en_US |
dc.subject | dosing system | en_US |
dc.subject | drop mass | en_US |
dc.subject | variability | en_US |
dc.title | Dávkování veterinárních očních kapek 1. | cs_CZ |
dc.type | diplomová práce | cs_CZ |
dcterms.created | 2022 | |
dcterms.dateAccepted | 2022-06-01 | |
dc.description.department | Department of Pharmaceutical Technology | en_US |
dc.description.department | Katedra farmaceutické technologie | cs_CZ |
dc.description.faculty | Farmaceutická fakulta v Hradci Králové | cs_CZ |
dc.description.faculty | Faculty of Pharmacy in Hradec Králové | en_US |
dc.identifier.repId | 227917 | |
dc.title.translated | Dosing of veterinary eye drops 1 | en_US |
dc.contributor.referee | Smékalová, Monika | |
thesis.degree.name | Mgr. | |
thesis.degree.level | magisterské | cs_CZ |
thesis.degree.discipline | Farmacie | cs_CZ |
thesis.degree.discipline | Pharmacy | en_US |
thesis.degree.program | Pharmacy | en_US |
thesis.degree.program | Farmacie | cs_CZ |
uk.thesis.type | diplomová práce | cs_CZ |
uk.taxonomy.organization-cs | Farmaceutická fakulta v Hradci Králové::Katedra farmaceutické technologie | cs_CZ |
uk.taxonomy.organization-en | Faculty of Pharmacy in Hradec Králové::Department of Pharmaceutical Technology | en_US |
uk.faculty-name.cs | Farmaceutická fakulta v Hradci Králové | cs_CZ |
uk.faculty-name.en | Faculty of Pharmacy in Hradec Králové | en_US |
uk.faculty-abbr.cs | FaF | cs_CZ |
uk.degree-discipline.cs | Farmacie | cs_CZ |
uk.degree-discipline.en | Pharmacy | en_US |
uk.degree-program.cs | Farmacie | cs_CZ |
uk.degree-program.en | Pharmacy | en_US |
thesis.grade.cs | Výborně | cs_CZ |
thesis.grade.en | Excellent | en_US |
uk.abstract.cs | Univerzita Karlova, Farmaceutická fakulta v Hradci Králové Katedra: Farmaceutická techonologie Školitel: doc. PharmDr. Zdeňka Šklubalová, Ph.D. Posluchač: Jana Marková Název diplomové práce: Dávkování veterinárních očních kapek 1. Cílem této diplomové práce bylo hodnocení vlivu rychlosti kapání, úhlu kapání (90ř, 65ř, 45ř) a objemu náplně lahvičky (30 ml, 15 ml, 5 ml) na hmotnost komerčních očních kapek určených k vakcinaci drůbeže. Kapky byly dispensovány manuálně z konvenčního dávkovacího systému (plastová 30 ml lahvička a kapátko) nebo pomocí prototypu poloautomatického dávkovacího zařízení. S vyšší dispenzační rychlostí se hmotnost kapek zvyšovala ve všech experimentálních kombinacích sledovaných v práci. Pro konvenční systém se při snížení dispenzačního úhlu hmotnost kapky snižovala pouze při konstantní rychlosti kapání, v ostatních situacích zejména při redukci objemu náplně na 15 ml a 5 ml se zvyšovala díky smáčení zaobleného kapátka. V důsledku toho rostla i variabilita dávky. Vliv objemu na výslednou hmotnost kapky byl při použití prototypu podle doporučení výrobcem nevýznamný. U studovaných suspenzních kapek však byla zaznamenána zvýšená variabilita dávky. | cs_CZ |
uk.abstract.en | Charles University, Faculty of Pharmacy in Hradec Králové Department of: Pharmaceutical technology Consultant: doc. PharmDr. Zdeňka Šklubalová, Ph.D. Student: Jana Marková Title of Thesis: Dosing of veterinary eye drops 1. The main purpose of this thesis was to find out, whether and to what extent the rate of dispensing, the dispending angle (90ř, 65ř, 45ř) and the volume of preparation (30 ml, 15 ml, 5 ml) had effected the mass of commercial eye drops for poultry vaccination. Drops were produced manually by using conventional dispensing system (plastic 30 ml dropper bottle and dropper tip) and by using a new prototype of semi-automatic device. The drop mass increased with increasing the rate of drop formation in every examined combination of factors. With decreasing of the dispensing angle, the drop mass decreased only in a case of constant rate dropping. In all other cases, especially with volume reduction to 15 ml and 5 ml, the drop size often increased due to the wetting of hemispherical dropper tip. As a result, higher variability of drop masses had occurred. With using the semi-automated prototype, the preparation volume had no impact on the final drop mass. On the other hand, higher variability of doses was noted for studied suspension eye drops. | en_US |
uk.file-availability | V | |
uk.grantor | Univerzita Karlova, Farmaceutická fakulta v Hradci Králové, Katedra farmaceutické technologie | cs_CZ |
thesis.grade.code | 1 | |
uk.publication-place | Hradec Králové | cs_CZ |
uk.thesis.defenceStatus | O | |