dc.contributor.advisor | Hronek, Miloslav | |
dc.creator | Žídková, Natálie | |
dc.date.accessioned | 2023-07-25T01:10:24Z | |
dc.date.available | 2023-07-25T01:10:24Z | |
dc.date.issued | 2023 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11956/181184 | |
dc.description.abstract | KATEDRA BIOLOGICKÝCH A LÉKAŘSKÝCH VĚD Hodnocení predikce tělesné kompozice měřené bioimpedanční Natálie Žídková Vedoucí diplomové práce: doc. PharmDr. Miloslav Hronek, Ph.D. HRADEC KRÁLOVÉ, 2022/2023 ABSTRACT The aim of this work was to evaluate the prediction of body composition by the method of dual bioimpedance analysis in relation to the prediction of body composition by the method of spectroscopic bioimpedance analysis. Five pregnant women (first-time mothers) with a physiologically ongoing pregnancy were included in the study. Each of them participated in three examinations, specifically in the period between 17.-27. week of pregnancy, 28.-35. week of pregnancy and the 36th-38th week of pregnancy. A Tanita RD-953 personal digital scale (Tanita Corporation, Tokyo, Japan) representing dual bioimpedance analysis and a BCM - Body Composition Monitor (Fresenius Medical Care, Bad Homburg, Germany) representing spectroscopic bioimpedance analysis were used for measurements. The measurement results were compared by statistical analysis. No significant differences were found between the BIA and BIS measurements by the Wilcoxon test. In contrast, the Bland-Altman test found statistically significant differences in the measurement of body fat in the first and second follow-up periods, as well as in the... | en_US |
dc.description.abstract | KATEDRA BIOLOGICKÝCH A LÉKAŘSKÝCH VĚD Hodnocení predikce tělesné kompozice měřené bioimpedanční Natálie Žídková Vedoucí diplomové práce: doc. PharmDr. Miloslav Hronek, Ph.D. HRADEC KRÁLOVÉ, 2022/2023 ABSTRAKT Cílem této práce bylo zhodnotit predikci tělesného složení metodou duální bioimpedanční analýzy vzhledem k predikci tělesného složení metodou spektroskopické bioimpedanční analýzy. Do studie bylo zařazeno pět těhotných žen (prvorodiček) s fyziologicky probíhajícím těhotenstvím. Každá z nich se zúčastnila tří vyšetření, konkrétně v období mezi 17.-27. týdnem gravidity, 28.-35. týdnem gravidity a 36.-38. týdnem gravidity. Pro měření byla využívána osobní digitální váha Tanita RD-953 (Tanita Corporation, Tokio, Japonsko) představující duální bioimpedanční analýzu a přístroj BCM - Body Composition Monitor (Fresenius Medical Care, Bad Homburg, Německo) představující spektroskopickou bioimpedanční analýzu. Výsledky měření byly porovnány pomocí statistické analýzy. Mezi měřeními metodou BIA a BIS nebyly Wilcoxonovým testem nalezeny žádné statisticky významné odchylky. Oproti tomu Bland-Altmanův test nalezl statisticky významné odlišnosti v měření tělesného tuku v prvním a druhém sledovaném období a dále v měření netučné složky v prvním sledovaném období. V případě predikce tělesného tuku byly mezi metodou BIA... | cs_CZ |
dc.language | Čeština | cs_CZ |
dc.language.iso | cs_CZ | |
dc.publisher | Univerzita Karlova, Farmaceutická fakulta v Hradci Králové | cs_CZ |
dc.subject | body fluids | en_US |
dc.subject | preganncy | en_US |
dc.subject | tělesné tekutiny | cs_CZ |
dc.subject | gravidita | cs_CZ |
dc.title | Hodnocení predikce tělesné kompozice měřené duální bioimpedancí ve srovnání s biompedanční spektroskopií. | cs_CZ |
dc.type | diplomová práce | cs_CZ |
dcterms.created | 2023 | |
dcterms.dateAccepted | 2023-05-30 | |
dc.description.department | Katedra biologických a lékařských věd | cs_CZ |
dc.description.department | Department of Biological and Medical Sciences | en_US |
dc.description.faculty | Faculty of Pharmacy in Hradec Králové | en_US |
dc.description.faculty | Farmaceutická fakulta v Hradci Králové | cs_CZ |
dc.identifier.repId | 239590 | |
dc.title.translated | Evaluation of the prediction of body composition measured by dual bioimpedance compared with bioimpedance spectroscopy. | en_US |
dc.contributor.referee | Herink, Josef | |
thesis.degree.name | Mgr. | |
thesis.degree.level | magisterské | cs_CZ |
thesis.degree.discipline | Farmacie | cs_CZ |
thesis.degree.discipline | Pharmacy | en_US |
thesis.degree.program | Farmacie | cs_CZ |
thesis.degree.program | Pharmacy | en_US |
uk.thesis.type | diplomová práce | cs_CZ |
uk.taxonomy.organization-cs | Farmaceutická fakulta v Hradci Králové::Katedra biologických a lékařských věd | cs_CZ |
uk.taxonomy.organization-en | Faculty of Pharmacy in Hradec Králové::Department of Biological and Medical Sciences | en_US |
uk.faculty-name.cs | Farmaceutická fakulta v Hradci Králové | cs_CZ |
uk.faculty-name.en | Faculty of Pharmacy in Hradec Králové | en_US |
uk.faculty-abbr.cs | FaF | cs_CZ |
uk.degree-discipline.cs | Farmacie | cs_CZ |
uk.degree-discipline.en | Pharmacy | en_US |
uk.degree-program.cs | Farmacie | cs_CZ |
uk.degree-program.en | Pharmacy | en_US |
thesis.grade.cs | Výborně | cs_CZ |
thesis.grade.en | Excellent | en_US |
uk.abstract.cs | KATEDRA BIOLOGICKÝCH A LÉKAŘSKÝCH VĚD Hodnocení predikce tělesné kompozice měřené bioimpedanční Natálie Žídková Vedoucí diplomové práce: doc. PharmDr. Miloslav Hronek, Ph.D. HRADEC KRÁLOVÉ, 2022/2023 ABSTRAKT Cílem této práce bylo zhodnotit predikci tělesného složení metodou duální bioimpedanční analýzy vzhledem k predikci tělesného složení metodou spektroskopické bioimpedanční analýzy. Do studie bylo zařazeno pět těhotných žen (prvorodiček) s fyziologicky probíhajícím těhotenstvím. Každá z nich se zúčastnila tří vyšetření, konkrétně v období mezi 17.-27. týdnem gravidity, 28.-35. týdnem gravidity a 36.-38. týdnem gravidity. Pro měření byla využívána osobní digitální váha Tanita RD-953 (Tanita Corporation, Tokio, Japonsko) představující duální bioimpedanční analýzu a přístroj BCM - Body Composition Monitor (Fresenius Medical Care, Bad Homburg, Německo) představující spektroskopickou bioimpedanční analýzu. Výsledky měření byly porovnány pomocí statistické analýzy. Mezi měřeními metodou BIA a BIS nebyly Wilcoxonovým testem nalezeny žádné statisticky významné odchylky. Oproti tomu Bland-Altmanův test nalezl statisticky významné odlišnosti v měření tělesného tuku v prvním a druhém sledovaném období a dále v měření netučné složky v prvním sledovaném období. V případě predikce tělesného tuku byly mezi metodou BIA... | cs_CZ |
uk.abstract.en | KATEDRA BIOLOGICKÝCH A LÉKAŘSKÝCH VĚD Hodnocení predikce tělesné kompozice měřené bioimpedanční Natálie Žídková Vedoucí diplomové práce: doc. PharmDr. Miloslav Hronek, Ph.D. HRADEC KRÁLOVÉ, 2022/2023 ABSTRACT The aim of this work was to evaluate the prediction of body composition by the method of dual bioimpedance analysis in relation to the prediction of body composition by the method of spectroscopic bioimpedance analysis. Five pregnant women (first-time mothers) with a physiologically ongoing pregnancy were included in the study. Each of them participated in three examinations, specifically in the period between 17.-27. week of pregnancy, 28.-35. week of pregnancy and the 36th-38th week of pregnancy. A Tanita RD-953 personal digital scale (Tanita Corporation, Tokyo, Japan) representing dual bioimpedance analysis and a BCM - Body Composition Monitor (Fresenius Medical Care, Bad Homburg, Germany) representing spectroscopic bioimpedance analysis were used for measurements. The measurement results were compared by statistical analysis. No significant differences were found between the BIA and BIS measurements by the Wilcoxon test. In contrast, the Bland-Altman test found statistically significant differences in the measurement of body fat in the first and second follow-up periods, as well as in the... | en_US |
uk.file-availability | V | |
uk.grantor | Univerzita Karlova, Farmaceutická fakulta v Hradci Králové, Katedra biologických a lékařských věd | cs_CZ |
thesis.grade.code | 1 | |
uk.publication-place | Hradec Králové | cs_CZ |
uk.thesis.defenceStatus | O | |