dc.contributor.advisor | Hubálková, Hana | |
dc.creator | Linetskiy, Igor | |
dc.date.accessioned | 2024-04-08T12:46:29Z | |
dc.date.available | 2024-04-08T12:46:29Z | |
dc.date.issued | 2024 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11956/188430 | |
dc.description.abstract | Magnetic resonance imaging (MRI) is one of the up-to-date and perspective methods of diagnostic medical imaging. It is highly valued for absence of ionizing radiation, non-invasiveness, acquiring of highly accurate images of hard and especially soft tissues in any plane. It is a method of choice in central nervous system imaging. Nowadays it is used in diagnostics of other diseases in the maxillofacial area. The major shortcoming of MRI is interaction of magnetic fields of MRI system with metallic objects present in human body. As a result, this may lead to their heating, movement, and also to imaging artifacts. Since different metallic constructions (fixed bridges, dental implants, splints, plates, orthodontic appliances, etc.) are often used in the contemporary dentistry, the problem of their compatibility with MRI is relevant. The aim of this study was to validate the compatibility of dental alloys with MRI, classify the materials according to the degree of compatibility and to establish the range of their possible negative impact on quality of MRI in head and neck area. In order to find dental metals and alloys, General Health Insurance Company code- list, catalogues of manufacturers' and Prague dental labs were used. Measurement methods of magnetic susceptibility (MS), electric conductivity... | en_US |
dc.description.abstract | Vyšetření magnetickou rezonancí (MR) je jednou z moderních a perspektivních metod medicínské vizualizace. Je ceněno pro absenci ionizujícího záření, neinvazivitu, získávání vysoce přesných zobrazení tvrdých a zejména měkkých tkání v libovolné rovině. Je metodou volby pro vyšetření centrální nervové soustavy. V poslední době se velmi často využívá v diagnostice onemocnění v maxilofaciální krajině. Hlavní slabinou MR je interakce magnetických polí s kovovými předměty přítomnými v těle člověka, její následkem může docházet k jejich ohřevu, pohybu a výskytu artefaktů MR obrazů. Vzhledem k tomu, že se v moderní stomatologii velmi často používají různé kovové konstrukce (fixní zubní náhrady, implantáty, dlahy, ortodontické aparáty aj.), otázka jejich kompatibility s MR prostředím je velmi aktuální. Cílem této práce bylo ověřit kompatibilitu dentálních slitin s prostředím MR, klasifikovat vybrané dentální slitiny dle stupně kompatibility s MR prostředím a stanovit rozsah jejich možného negativního vlivu na kvalitu MR vyšetření v oblasti hlavy a krku. Pro vyhledání dentálních kovů a slitin byl použit číselník VZP (Stomatologické výrobky), katalogy výrobců a distributorů dentálních slitin a nabídka zpracovávaných kovů a slitin v pražských zubních laboratořích. Jsou zde popsány metodiky stanovení magnetické... | cs_CZ |
dc.language | Čeština | cs_CZ |
dc.language.iso | cs_CZ | |
dc.publisher | Univerzita Karlova, 1. lékařská fakulta | cs_CZ |
dc.subject | magnetická rezonance | cs_CZ |
dc.subject | magnetická susceptibilita | cs_CZ |
dc.subject | elektrická vodivost | cs_CZ |
dc.subject | kovové dentální materiály | cs_CZ |
dc.subject | ohřev | cs_CZ |
dc.subject | pohyb | cs_CZ |
dc.subject | artefakty obrazu | cs_CZ |
dc.subject | sekvence | cs_CZ |
dc.subject | kompatibilita | cs_CZ |
dc.subject | Magnetic resonance imaging | en_US |
dc.subject | magnetic susceptibility | en_US |
dc.subject | electric conductivity | en_US |
dc.subject | metallic dental materials | en_US |
dc.subject | heating | en_US |
dc.subject | movement | en_US |
dc.subject | image artifacts | en_US |
dc.subject | sequence | en_US |
dc.subject | compatibility | en_US |
dc.title | Kompatibilita vybraných dentálních slitin s metodou vyšetření magnetickou rezonancí | cs_CZ |
dc.type | dizertační práce | cs_CZ |
dcterms.created | 2024 | |
dcterms.dateAccepted | 2024-02-08 | |
dc.description.department | Department of Dental Medicine First Faculty of Medicine Charles University and General University Hospital in Prague | en_US |
dc.description.department | Stomatologická klinika 1. LF UK a VFN | cs_CZ |
dc.description.faculty | First Faculty of Medicine | en_US |
dc.description.faculty | 1. lékařská fakulta | cs_CZ |
dc.identifier.repId | 156321 | |
dc.title.translated | Compatibility of selected dental alloys with magnetic resonance imaging | en_US |
dc.contributor.referee | Suchánek, Jakub | |
dc.contributor.referee | Dostálová, Taťjana | |
thesis.degree.name | Ph.D. | |
thesis.degree.level | doktorské | cs_CZ |
thesis.degree.discipline | Experimental Surgery | en_US |
thesis.degree.discipline | Experimentální chirurgie | cs_CZ |
thesis.degree.program | Experimental Surgery | en_US |
thesis.degree.program | Experimentální chirurgie | cs_CZ |
uk.thesis.type | dizertační práce | cs_CZ |
uk.taxonomy.organization-cs | 1. lékařská fakulta::Stomatologická klinika 1. LF UK a VFN | cs_CZ |
uk.taxonomy.organization-en | First Faculty of Medicine::Department of Dental Medicine First Faculty of Medicine Charles University and General University Hospital in Prague | en_US |
uk.faculty-name.cs | 1. lékařská fakulta | cs_CZ |
uk.faculty-name.en | First Faculty of Medicine | en_US |
uk.faculty-abbr.cs | 1.LF | cs_CZ |
uk.degree-discipline.cs | Experimentální chirurgie | cs_CZ |
uk.degree-discipline.en | Experimental Surgery | en_US |
uk.degree-program.cs | Experimentální chirurgie | cs_CZ |
uk.degree-program.en | Experimental Surgery | en_US |
thesis.grade.cs | Prospěl/a | cs_CZ |
thesis.grade.en | Pass | en_US |
uk.abstract.cs | Vyšetření magnetickou rezonancí (MR) je jednou z moderních a perspektivních metod medicínské vizualizace. Je ceněno pro absenci ionizujícího záření, neinvazivitu, získávání vysoce přesných zobrazení tvrdých a zejména měkkých tkání v libovolné rovině. Je metodou volby pro vyšetření centrální nervové soustavy. V poslední době se velmi často využívá v diagnostice onemocnění v maxilofaciální krajině. Hlavní slabinou MR je interakce magnetických polí s kovovými předměty přítomnými v těle člověka, její následkem může docházet k jejich ohřevu, pohybu a výskytu artefaktů MR obrazů. Vzhledem k tomu, že se v moderní stomatologii velmi často používají různé kovové konstrukce (fixní zubní náhrady, implantáty, dlahy, ortodontické aparáty aj.), otázka jejich kompatibility s MR prostředím je velmi aktuální. Cílem této práce bylo ověřit kompatibilitu dentálních slitin s prostředím MR, klasifikovat vybrané dentální slitiny dle stupně kompatibility s MR prostředím a stanovit rozsah jejich možného negativního vlivu na kvalitu MR vyšetření v oblasti hlavy a krku. Pro vyhledání dentálních kovů a slitin byl použit číselník VZP (Stomatologické výrobky), katalogy výrobců a distributorů dentálních slitin a nabídka zpracovávaných kovů a slitin v pražských zubních laboratořích. Jsou zde popsány metodiky stanovení magnetické... | cs_CZ |
uk.abstract.en | Magnetic resonance imaging (MRI) is one of the up-to-date and perspective methods of diagnostic medical imaging. It is highly valued for absence of ionizing radiation, non-invasiveness, acquiring of highly accurate images of hard and especially soft tissues in any plane. It is a method of choice in central nervous system imaging. Nowadays it is used in diagnostics of other diseases in the maxillofacial area. The major shortcoming of MRI is interaction of magnetic fields of MRI system with metallic objects present in human body. As a result, this may lead to their heating, movement, and also to imaging artifacts. Since different metallic constructions (fixed bridges, dental implants, splints, plates, orthodontic appliances, etc.) are often used in the contemporary dentistry, the problem of their compatibility with MRI is relevant. The aim of this study was to validate the compatibility of dental alloys with MRI, classify the materials according to the degree of compatibility and to establish the range of their possible negative impact on quality of MRI in head and neck area. In order to find dental metals and alloys, General Health Insurance Company code- list, catalogues of manufacturers' and Prague dental labs were used. Measurement methods of magnetic susceptibility (MS), electric conductivity... | en_US |
uk.file-availability | V | |
uk.grantor | Univerzita Karlova, 1. lékařská fakulta, Stomatologická klinika 1. LF UK a VFN | cs_CZ |
thesis.grade.code | P | |
uk.publication-place | Praha | cs_CZ |
uk.thesis.defenceStatus | O | |