dc.contributor.advisor | Trunda, Otakar | |
dc.creator | Kubový, Jan | |
dc.date.accessioned | 2024-04-08T09:38:46Z | |
dc.date.available | 2024-04-08T09:38:46Z | |
dc.date.issued | 2024 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11956/188478 | |
dc.description.abstract | In collaboration with the Institute for Clinical and Experimental Medicine (IKEM) and leveraging their historical examination data, we developed a convolutional neural net- work trained to identify diabetic retinopathy from retinal images. The primary objective of this project was to establish a machine learning model applicable within the medi- cal setting of IKEM, streamlining and potentially expediting the examination process. Additionally, we designed a user-friendly website to facilitate the straightforward utiliza- tion of the trained model by physicians possessing only basic computer skills. While the neural network demonstrates good results, it is crucial to underscore its restricted adapt- ability, attributed to the compact model size and the monotonic nature of ophthalmic data sourced from a specific type of fundus camera. The proposed solution is slated for testing in a real hospital operational environment. The neural network is not intended as a replacement for the physician, but as a tool that can assist the physician in diagnostic process. 1 | en_US |
dc.description.abstract | Ve spolupráci s Institutem klinické a experimentální medicíny (IKEM) a jejich histo- rických dat z vyšetření byla natrénována konvoluční neuronová síť rozpoznávající diabe- tickou retinopatii ze snímků sítnice. Cílem práce bylo vytvořit model strojového učení, který bude možné využít ve zdravotnickém zařízení IKEM za cílem zjednodušit a pří- padně zrychlit vyšetření. Součástí projektu byla také tvorba webové stránky, která umož- ňuje snadné spouštění natrénovaného modelu lékařem s pouze základní znalostí ovládání počítače. I přesto, že neuronová síť dosahuje dobrých výsledků, je třeba zdůraznit její omezenou univerzálnost z důvodu malé velikosti modelu a jednotvárnosti poskytnutých oftalmologických dat z jednoho typu fundus kamery. Navržené řešení bude podrobeno testování v provozním prostředí nemocnice. Neuronová síť není zamýšlena jako náhrada lékaře, ale jako nástroj, který mu může asistovat v diagnostickém procesu. 1 | cs_CZ |
dc.language | Čeština | cs_CZ |
dc.language.iso | cs_CZ | |
dc.publisher | Univerzita Karlova, Matematicko-fyzikální fakulta | cs_CZ |
dc.subject | Strojové učení|Zpracování obrazu|Retinopatie|Neuronové sítě|Diagnóza | cs_CZ |
dc.subject | Machine Learning|Image Processing|Retinopathy|Neural networks|Medical diagnosis | en_US |
dc.title | Rozpoznávání retinopatie ve snímcích sítnice pomocí strojového učení | cs_CZ |
dc.type | diplomová práce | cs_CZ |
dcterms.created | 2024 | |
dcterms.dateAccepted | 2024-02-13 | |
dc.description.department | Department of Theoretical Computer Science and Mathematical Logic | en_US |
dc.description.department | Katedra teoretické informatiky a matematické logiky | cs_CZ |
dc.description.faculty | Faculty of Mathematics and Physics | en_US |
dc.description.faculty | Matematicko-fyzikální fakulta | cs_CZ |
dc.identifier.repId | 238418 | |
dc.title.translated | Retinopathy Detection in Retina Images using Machine Learning | en_US |
dc.contributor.referee | Holeňa, Martin | |
thesis.degree.name | Mgr. | |
thesis.degree.level | navazující magisterské | cs_CZ |
thesis.degree.discipline | Artificial Intelligence | en_US |
thesis.degree.discipline | Umělá inteligence | cs_CZ |
thesis.degree.program | Computer Science | en_US |
thesis.degree.program | Informatika | cs_CZ |
uk.thesis.type | diplomová práce | cs_CZ |
uk.taxonomy.organization-cs | Matematicko-fyzikální fakulta::Katedra teoretické informatiky a matematické logiky | cs_CZ |
uk.taxonomy.organization-en | Faculty of Mathematics and Physics::Department of Theoretical Computer Science and Mathematical Logic | en_US |
uk.faculty-name.cs | Matematicko-fyzikální fakulta | cs_CZ |
uk.faculty-name.en | Faculty of Mathematics and Physics | en_US |
uk.faculty-abbr.cs | MFF | cs_CZ |
uk.degree-discipline.cs | Umělá inteligence | cs_CZ |
uk.degree-discipline.en | Artificial Intelligence | en_US |
uk.degree-program.cs | Informatika | cs_CZ |
uk.degree-program.en | Computer Science | en_US |
thesis.grade.cs | Velmi dobře | cs_CZ |
thesis.grade.en | Very good | en_US |
uk.abstract.cs | Ve spolupráci s Institutem klinické a experimentální medicíny (IKEM) a jejich histo- rických dat z vyšetření byla natrénována konvoluční neuronová síť rozpoznávající diabe- tickou retinopatii ze snímků sítnice. Cílem práce bylo vytvořit model strojového učení, který bude možné využít ve zdravotnickém zařízení IKEM za cílem zjednodušit a pří- padně zrychlit vyšetření. Součástí projektu byla také tvorba webové stránky, která umož- ňuje snadné spouštění natrénovaného modelu lékařem s pouze základní znalostí ovládání počítače. I přesto, že neuronová síť dosahuje dobrých výsledků, je třeba zdůraznit její omezenou univerzálnost z důvodu malé velikosti modelu a jednotvárnosti poskytnutých oftalmologických dat z jednoho typu fundus kamery. Navržené řešení bude podrobeno testování v provozním prostředí nemocnice. Neuronová síť není zamýšlena jako náhrada lékaře, ale jako nástroj, který mu může asistovat v diagnostickém procesu. 1 | cs_CZ |
uk.abstract.en | In collaboration with the Institute for Clinical and Experimental Medicine (IKEM) and leveraging their historical examination data, we developed a convolutional neural net- work trained to identify diabetic retinopathy from retinal images. The primary objective of this project was to establish a machine learning model applicable within the medi- cal setting of IKEM, streamlining and potentially expediting the examination process. Additionally, we designed a user-friendly website to facilitate the straightforward utiliza- tion of the trained model by physicians possessing only basic computer skills. While the neural network demonstrates good results, it is crucial to underscore its restricted adapt- ability, attributed to the compact model size and the monotonic nature of ophthalmic data sourced from a specific type of fundus camera. The proposed solution is slated for testing in a real hospital operational environment. The neural network is not intended as a replacement for the physician, but as a tool that can assist the physician in diagnostic process. 1 | en_US |
uk.file-availability | V | |
uk.grantor | Univerzita Karlova, Matematicko-fyzikální fakulta, Katedra teoretické informatiky a matematické logiky | cs_CZ |
thesis.grade.code | 2 | |
uk.publication-place | Praha | cs_CZ |
uk.thesis.defenceStatus | O | |