Voltametrická detekce 27-hydroxycholesterolu na borem dopované diamantové elektrodě
Voltammetric detection of 27-hydroxycholesterol on boron-doped diamond electrode
bachelor thesis (DEFENDED)
Item with restricted access
Whole item or its parts have restricted access until 05. 06. 2027
Reason for restricted acccess:
Protection of intellectual property, particularly protection of inventions or technical solutions
View/ Open
Permanent link
http://hdl.handle.net/20.500.11956/190227Identifiers
Study Information System: 266861
Collections
- Kvalifikační práce [20091]
Author
Advisor
Referee
Nesměrák, Karel
Faculty / Institute
Faculty of Science
Discipline
Clinical and Toxicological Analysis
Department
Department of Analytical Chemistry
Date of defense
4. 6. 2024
Publisher
Univerzita Karlova, Přírodovědecká fakultaLanguage
Czech
Grade
Excellent
Keywords (Czech)
27-hydroxycholesterol, borem dopovaná diamantová elektroda, oxidace, oxysteroly, voltametrieKeywords (English)
27-hydroxycholesterol, boron-doped diamond electrode, oxidation, oxysterols, voltammetryCílem této bakalářské práce bylo studium voltametrického chování 27-hydroxycholesterolu za využití borem dopované diamantové elektrody. Byl zkoumán vliv několika faktorů na proudovou odezvu 27-hydroxycholesterolu: vliv základního elektrolytu, koncentrace kyseliny chloristé, rychlosti polarizace, obsahu vody a vliv pH. Studium bylo prováděno metodou cyklické voltametrie v prostředí kyseliny chloristé nebo v prostředí chloristanu sodného v acetonitrilu. 27-hydroxycholesterol poskytuje v prostředí 0,1 mol l-1 kyseliny chloristé v acetonitrilu (obsah vody 0,43 %) a 0,1 mol l-1 chloristanu sodného v acetonitrilu proudovou odezvu v anodické oblasti s potenciálem okolo +1450 mV vs. Ag/0,01 mol l-1 AgNO3 v 1 mol l-1 NaClO4 v acetonitrilu. Dále byla naměřena koncentrační závislost metodou diferenční pulzní voltametrie s limitem detekce (LOD) stanoveným na 2,71 μmol l-1 a limitem stanovitelnosti (LOQ) stanoveným na 9,04 μmol l-1 . Bylo prokázáno, že metoda voltametrie s lineárním nárůstem potenciálů nedosahuje srovnatelných limitních hodnot. Klíčová slova 27-hydroxycholesterol, borem dopovaná diamantová elektroda, oxidace, oxysteroly, voltametrie
The aim of this bachelor thesis was to study the voltammetric behavior of 27-hydroxycholesterol using boron-doped diamond electrode. The influence of several factors on the current response of 27-hydroxycholesterol was investigated: the effect of the supporting electrolyte, concentration of perchloric acid, polarization rate, water content, and pH effect. The study was conducted using cyclic voltammetry in a perchloric acid or sodium perchlorate in acetonitrile. 27-hydroxycholesterol provided a current response in the anodic region with a potential around +1450 mV vs. Ag/0.01 mol l-1 AgNO3 in 1 mol l-1 NaClO4 in acetonitrile in the presence of 0.1 mol l−1 perchloric acid in acetonitrile (water content 0.43 %) and 0.1 mol l−1 sodium perchlorate in acetonitrile. Furthermore, concentration dependence was measured using differential pulse voltammetry resulting in a limit of detection (LOD) of 2.71 μmol l−1 and a limit of quantitation (LOQ) of 9.04 μmol l−1 . It was demonstrated that the direct current voltammetry method does not achieve comparable limit values. Key words 27-hydroxycholesterol, boron-doped diamond electrode, oxidation, oxysterols, voltammetry