Germicidal effects of corona discharge on microorganisms
dc.contributor.advisorKříha, Vítězslav
dc.creatorDymáčková, Laura
dc.date.accessioned2017-04-12T15:46:23Z
dc.date.available2017-04-12T15:46:23Z
dc.date.issued2008
dc.identifier.urihttp://hdl.handle.net/20.500.11956/1280
dc.description.abstractThis thesis following up the studies about decontamination effects of low-temperature plasma generated by corona discharge. Two species of bacteria, Escherichia coli and Staphylococcus epidermidis, were exposed in two separate sets of experiments. Bacterial suspensions were treated by point-to-plane corona discharge directly on surface of semisolid culture medium, the Mueller-Hinton agar, placed in Petri Dishes of 5 cm diameter. The point electrode was realized by the tip of a 0.7 mm syringe needle, connected to the source of direct current high voltage. The plane electrode was formed by the surface of an ion-conducting semisolid cultivation medium. A micrometer screw allowed precise setting the 4 mm distance of the point electrode from the anode surface. The samples were exposed to the corona discharge with current of 25μA - 150μA range. The treatment duration is given by constant exposed charge (18, 27, 36 and 54 mC) condition. After exposition, all Petri dishes were immediately cultivated at 37 žC overnight. After cultivation followed evaluation of inhibition zone areas, that was caused by action of electric charge. The state of the cultures was quantitatively assessed by measuring of the growth inhibition zones, where a complete growth inhibition took place. The behaviors of these exposures were...en_US
dc.languageČeštinacs_CZ
dc.language.isocs_CZ
dc.publisherUniverzita Karlova, Přírodovědecká fakultacs_CZ
dc.titleCidní působení korónového výboje na mikroorganismycs_CZ
dc.typediplomová prácecs_CZ
dcterms.created2008
dcterms.dateAccepted2008-09-23
dc.description.departmentKatedra genetiky a mikrobiologiecs_CZ
dc.description.departmentDepartment of Genetics and Microbiologyen_US
dc.description.facultyFaculty of Scienceen_US
dc.description.facultyPřírodovědecká fakultacs_CZ
dc.identifier.repId60926
dc.title.translatedGermicidal effects of corona discharge on microorganismsen_US
dc.contributor.refereeJulák, Jaroslav
dc.identifier.aleph000999367
thesis.degree.nameMgr.
thesis.degree.levelmagisterskécs_CZ
thesis.degree.disciplineUčitelství všeobecně vzdělávacích předmětů pro střední školy chemie - biologiecs_CZ
thesis.degree.disciplineTeaching of Chemistry and Biology for Secondary Schoolsen_US
thesis.degree.programChemiecs_CZ
thesis.degree.programChemistryen_US
uk.thesis.typediplomová prácecs_CZ
uk.taxonomy.organization-csPřírodovědecká fakulta::Katedra genetiky a mikrobiologiecs_CZ
uk.taxonomy.organization-enFaculty of Science::Department of Genetics and Microbiologyen_US
uk.faculty-name.csPřírodovědecká fakultacs_CZ
uk.faculty-name.enFaculty of Scienceen_US
uk.faculty-abbr.csPřFcs_CZ
uk.degree-discipline.csUčitelství všeobecně vzdělávacích předmětů pro střední školy chemie - biologiecs_CZ
uk.degree-discipline.enTeaching of Chemistry and Biology for Secondary Schoolsen_US
uk.degree-program.csChemiecs_CZ
uk.degree-program.enChemistryen_US
thesis.grade.csDobřecs_CZ
thesis.grade.enGooden_US
uk.abstract.enThis thesis following up the studies about decontamination effects of low-temperature plasma generated by corona discharge. Two species of bacteria, Escherichia coli and Staphylococcus epidermidis, were exposed in two separate sets of experiments. Bacterial suspensions were treated by point-to-plane corona discharge directly on surface of semisolid culture medium, the Mueller-Hinton agar, placed in Petri Dishes of 5 cm diameter. The point electrode was realized by the tip of a 0.7 mm syringe needle, connected to the source of direct current high voltage. The plane electrode was formed by the surface of an ion-conducting semisolid cultivation medium. A micrometer screw allowed precise setting the 4 mm distance of the point electrode from the anode surface. The samples were exposed to the corona discharge with current of 25μA - 150μA range. The treatment duration is given by constant exposed charge (18, 27, 36 and 54 mC) condition. After exposition, all Petri dishes were immediately cultivated at 37 žC overnight. After cultivation followed evaluation of inhibition zone areas, that was caused by action of electric charge. The state of the cultures was quantitatively assessed by measuring of the growth inhibition zones, where a complete growth inhibition took place. The behaviors of these exposures were...en_US
uk.file-availabilityV
uk.publication.placePrahacs_CZ
uk.grantorUniverzita Karlova, Přírodovědecká fakulta, Katedra genetiky a mikrobiologiecs_CZ
dc.identifier.lisID990009993670106986


Soubory tohoto záznamu

Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail

Tento záznam se objevuje v následujících sbírkách

Zobrazit minimální záznam


© 2017 Univerzita Karlova, Ústřední knihovna, Ovocný trh 560/5, 116 36 Praha 1; email: admin-repozitar [at] cuni.cz

Za dodržení všech ustanovení autorského zákona jsou zodpovědné jednotlivé složky Univerzity Karlovy. / Each constituent part of Charles University is responsible for adherence to all provisions of the copyright law.

Upozornění / Notice: Získané informace nemohou být použity k výdělečným účelům nebo vydávány za studijní, vědeckou nebo jinou tvůrčí činnost jiné osoby než autora. / Any retrieved information shall not be used for any commercial purposes or claimed as results of studying, scientific or any other creative activities of any person other than the author.

DSpace software copyright © 2002-2015  DuraSpace
Theme by 
@mire NV